This One Setting on Your Charge Controller Can Save Your Battery Life
Most Nigerians don’t know this, but your solar battery can fail years earlier than expected simply because of one wrong setting on your charge controller.
You may have:
- The best solar panels
- A strong inverter
- Expensive lithium or tubular batteries
- Even a professional installation
…but if this ONE setting is wrong, your battery will:
- Overcharge
- Undercharge
- Swell
- Heat up
- Lose capacity
- Or die completely
Today, I’ll show you the exact setting you MUST fix — and how to set it correctly.
Let’s dive in.
The Hidden Setting: Battery Type Selection
Most charge controllers come with these battery type options:
- Li (Lithium)
- FLD (Flooded battery)
- SLD (Sealed AGM/GEL)
- USER (Custom settings)
If this is set wrongly, your battery is in danger.
✔ Why this setting matters
Each battery type has specific:
- Charging voltage
- Float voltage
- Absorption voltage
- Cut-off limits
- Boost time
- Temperature tolerance
When you select the wrong battery type:
❌ A lithium battery may overcharge
Lithium batteries CANNOT tolerate overvoltage. One wrong volt can:
- Swell the battery
- Ruin the BMS
- Permanently reduce capacity
❌ A GEL/AGM battery may undercharge
If undercharged over time, lead-acid batteries will:
- Sulphate
- Lose capacity
- Fail prematurely
❌ Flooded batteries may boil
Wrong absorption settings = water loss = damaged plates.
This is why your battery might be dying fast — and you never knew the cause.
How to Set the Correct Battery Type (Very Important)
✔ 1. Lithium (LiFePO4) Battery Setting
If you use:
- LiFePO4
- LFP battery
- Lithium solar battery
Select:
“Li” or “Lithium” mode
If your charge controller does NOT have lithium mode, switch to:
USER (Custom)
Then set:
- Bulk/Absorption: 14.4V (for 12V battery)
- Float: OFF or 13.6–13.8V
- Boost duration: 0–20 mins
Lithium batteries DO NOT need equalisation.
Turn it OFF.
✔ 2. GEL / AGM Battery Setting
Select:
“GEL” or “SLD”
Typical values:
- Bulk: 14.2–14.4V
- Float: 13.6–13.8V
- Equalization: OFF
✔ 3. Flooded Battery Setting
Select:
“FLD”
Typical values:
- Bulk: 14.6–14.8V
- Float: 13.5–13.7V
- Equalization: ON (depending on manufacturer)
What Happens When This Setting Is Wrong?
Here are the common problems Nigerians face without knowing the cause:
🔥 Fast battery drain
Incorrect charge voltage = incomplete charging.
🔥 Battery swelling
Mostly happens when lithium batteries are set to “FLD”.
🔥 Inverter low-voltage shutdown
Caused by undercharging.
🔥 Solar not lasting till morning
Because the battery never charges fully.
🔥 Overheating
Triggered by overvoltage.
🔥 Short battery lifespan
Your battery can die in 6 months instead of 5 years.
This is why this single setting is a lifesaver.
How to Know the Correct Battery Specs
Before setting your charge controller, check:
- The battery label
- The battery manual
- Manufacturer’s recommended voltage settings
Or simply use a solar sizing tool like the Globisun Solar App which includes proper battery configuration guides.
👉Download Globisun for proper solar sizing and battery setup
Bonus: 3 More Things You Must Set Correctly
1. Low Voltage Protection (LVP)
Set this too low, and you destroy your battery.
Set this too high, and the inverter keeps shutting off.
Recommended LVP:
- Lithium: 10.5–11.0V (per 12V)
- AGM/GEL: 10.8–11.2V
- Flooded: 10.5–11V
2. Temperature Compensation
Lead-acid needs it.
Lithium does NOT.
Turn OFF temperature compensation for LiFePO₄.
3. Maximum Charging Current
Lithium can handle higher charge; GEL cannot.
Typical rule:
- Lithium: 0.3–0.5C
- AGM/GEL: 0.1–0.2C
Final Word: Don’t Ignore This Setting
Most Nigerians destroy their batteries unknowingly through:
❌ Wrong charge controller settings
❌ Wrong battery type selection
❌ Wrong voltage
❌ Overcharging
❌ Undercharging
But with the correct battery type setting, your battery will:
- Charge correctly
- Last longer
- Hold power till morning
- Avoid swelling
- Maintain good performance for years