Solar Installations

10 Solar Mounting Mistakes You’re Probably Making

When it comes to solar installations, solar mounting is one of those things that looks simple—until something goes wrong. I’ve seen it all: panels shifting after a few months, leaks from poorly sealed penetrations, or systems producing less power than expected—all because of small mounting errors.

Whether you’re a new installer or a seasoned pro, it’s easy to overlook details when you’re focused on getting the system live. But the truth is, your solar mounting decisions directly affect system performance, lifespan, and even safety. In this post, I’ll break down the most common solar mounting mistakes I’ve seen (and made myself early on), plus practical fixes you can start applying right away.


solar mounting

1. Ignoring Roof Orientation and Pitch

One of the biggest mistakes I see in solar mounting is assuming every roof works the same.
If your panels aren’t angled correctly or face the wrong direction, you’re automatically losing potential energy output.

  • Example: I once reviewed a system where panels faced 30° west instead of south—output dropped by nearly 18%.
  • Fix: Always measure the roof azimuth and pitch angle before drilling your first hole. Use tools like the Globisun app to size your system and confirm ideal panel orientation for maximum solar gain.

Takeaway: A few degrees off-angle can cost your client thousands over the system’s lifetime.


2. Overlooking Structural Load Calculations

Your solar mounting system must work with the roof, not against it. Many installers skip proper load assessments—especially on older or lightweight structures.

  • Example: A client’s corrugated roof started sagging after six months because the rail spacing didn’t distribute the panel weight evenly.
  • Fix: Always calculate static and dynamic loads (wind, snow, and seismic if applicable). Follow manufacturer spacing specs religiously.

Takeaway: Proper load analysis isn’t optional—it’s your system’s foundation.


3. Using the Wrong Mounting Hardware

Mixing components from different manufacturers might seem harmless, but it can lead to misalignment and structural failure.

  • Example: A team once combined rails from one brand with clamps from another; half the clamps didn’t lock properly.
  • Fix: Stick to manufacturer-certified kits and use stainless steel hardware to avoid corrosion.

Takeaway: Compatibility and material integrity are just as important as your panels themselves.


4. Poor Roof Penetration Sealing

Water leaks are one of the fastest ways to destroy customer trust—and your reputation.

  • Example: A small crack around a lag bolt turned into a full ceiling leak during the first rainy season.
  • Fix: Always use flashing under every roof penetration, and seal with UV-rated, waterproof sealant. Don’t rush this step—it’s your first defense against water ingress.

Takeaway: A watertight seal today prevents costly callbacks tomorrow.


5. Inconsistent Rail Alignment

Crooked panels might still produce power—but they’ll look unprofessional and complicate maintenance.

  • Example: I once saw a system where misaligned rails caused one panel corner to lift under wind pressure.
  • Fix: Use a laser level or string line to keep all rails perfectly parallel. Double-check before tightening the last bolts.

Takeaway: Precision in alignment is both an aesthetic and performance factor.


6. Neglecting Thermal Expansion Gaps

Aluminum rails expand and contract with temperature changes. Ignoring expansion gaps can cause buckling or even panel cracking over time.

  • Fix: Leave small, manufacturer-recommended gaps (usually 5–10 mm) between rails.

Takeaway: Respecting expansion space ensures long-term mounting integrity.


7. Skipping Grounding and Bonding

A solid electrical ground is essential for safety and compliance—but some installers rely on panel frames alone.

  • Fix: Always use grounding lugs and bonding jumpers between rails. Confirm continuity with a multimeter.

Takeaway: Grounding is not optional—it’s your system’s insurance against shocks and fire hazards.


8. Improper Clamp Placement

End and mid clamps should sit precisely on the panel frame’s designated zones. Incorrect placement can cause cracking or loosened panels.

  • Fix: Follow the manufacturer’s torque settings and mounting zone diagram for each module type.

Takeaway: Small positioning errors can have big mechanical consequences.


9. Ignoring Wind Zones and Local Codes

Each area has specific wind load requirements, especially in coastal or high-altitude regions. Many installers use one-size-fits-all mounting configurations.

  • Fix: Check your local building codes and use the correct anchoring method. In high-wind areas, consider shorter rail spans and more mounting points.

Takeaway: Local conditions matter—install like you’re building for your own home.


10. Failing to Test Before Completion

After installation, most installers jump straight to inverter setup—but mounting stability should be checked first.

  • Fix: Perform a manual shake test on panels, confirm all fasteners are torqued, and inspect seals before powering on.

Takeaway: A 10-minute inspection can save you from weeks of post-installation issues.


Conclusion: Mount Smart, Not Fast

Solar mounting might seem routine, but it’s where most performance and reliability issues begin. When you approach every project with precision, attention to detail, and the right tools, your installs will stand the test of time.

If you want to take your installations to the next level, start by mastering your solar mounting process and leveraging tools that simplify accuracy. Apps like Globisun can help you size systems, check orientations, and optimize your mounting setup before you even step on-site.

Because at the end of the day, the best installers aren’t the fastest—they’re the ones who get it right the first time.